※ Please be sure to inform us of the items listed "〇". Explanation of each item
Operating condition 〇 Operating pressure (MPaG) Please state the normal operating pressure.
〇 Vacuum If it has a vacuum, please state the pressure range and the pressure cycle.
〇 Back pressure If it has a back pressure, please state if the pressure is always applied.
〇 Pulsation If it has pulsation, please state the pressure range and the pressure cycle.
Operating temperature (degreeC) Please state the normal operating temperature.
〇 Temperature cycle If it has a temperature cycle in the operation, please state the temperature range and the cycle.
〇 Fluid Type Please state the fluid information including the type, such as gas or liquid.
Molecular weight or specific gravity  
Amount of a necessary blow (kg/h)  
Coefficient/compression factor by k and P2/P1  
Applied standard Structural standard of the pressure container  
High Pressure Gas Safety Act  
Other standard if any  
Disk 〇 Size (nominal diameter)  
〇 Burst pressures (MPaG) Please state the design pressure value when the rupture disk burst.
Tolerance (MPa)  
〇 Bursting temperature (degreeC) Please state the temperature when the rupture disk burst.
Material Disk  
Outside treatment  
〇 Quantity 4pieces are standard, but 1piece is also acceptable.
Holder 〇 Size (nominal diameter)  
〇 Connect standard (JIS, ANSI, JPI, API, etc.) A custom-made part can be made.
Please feel free to contact us.
Upstream holder Material  
Outside treatment  
Connect shape (RF, T&G, RJ, SW, BW, etc.)  
Downstream holder Material  
Outside treatment  
Connect shape (RF, T&G, RJ, SW, BW, etc.) A custom-made part can be made.
Please feel free to contact us.
Accessories Excess flow valve Please inform us if a desired material is necessary.
Stud bolt and nut Please inform us if a desired material is necessary.
Gasket Please inform us if a desired material is necessary.
Others  
〇 Quantity  
〇 Rupture disk mounting operate position Please tell us the installation position of piping; Horizontal or Vertical.
〇 Which gasket type will be used between rupture disk holder and flange. If you're unable to decide, we can recommend the correct gasket.
〇 Use (purpose of use, environment of use) We will propose a rupture disk suitable for the application.

Related information

CONTACT

Rupture Disk Inquiry

Mail

Inquiry from Web

Inquiry Form

Request for Quotation

Quotation request through Web

Quotation request

Phone number

Inquiry by phone

(VTEX JAPAN)
+81-3-3765-4161

(VTEX AMERICA)
+1-408-432-7277

(VTEX KOREA)
+82-31-686-5381

(VTEX CHINA)
+86-(0)21-6295-0800

Copyright © V-TEX Corporation. All Rights Reserved.